Empowering Zero Emission: Duo-Plasmaline Driving Performance and Efficiency of Fuel Cells

How plasma technology solves the challenge of performance degradation in fuel cells

Fuel cells based on ionomer membranes are very important in applications such as zero emissions vehicles. The major disadvantage of commercially available membranes, e.g., Nafion, in direct methanol fuel cells (DMFC) is their relatively large permeability for methanol, which leads to a drastic degradation of the efficiency of the fuel cell. Figure 8 shows the schematic of a DMFC. Plasma surface treatment of such membranes can reduce their permeability to methanol. In addition, the bond strength of the membrane to the catalyst can be significantly improved by plasma surface treatment.

 

Figure 1: Schematic of a direct methanol fuel cell (DMFC) [8-9].

1. Plasma technology to improve water management issues

The porous gas diffusion layer (GDL) is another important component of a fuel cell. It provides a homogeneous gas flow to the catalyst and controls the water content of the cell. In particular, the water management over a wide range of the voltage/current polarization curves is very important for the efficiency of the fuel cell. However, GDLs mostly consist of a strongly hydrophobic material which is critical for a proper water management. A partially hydrophilic GDL is a better choice because it can retain a certain amount of water in the fuel cell.

 

Figure 2: Completely hydrophobic surface of a gas diffusion layer (GDL) showing hydrophilic properties of the areas exposed to the microwave plasma (cf. water droplets adhered to these hydrophilic areas after low-pressure microwave plasma treatment) [9-10].

 

Partially hydrophilic properties of the GDL can be achieved by e.g., surface treatment of the GDL in a nitrogen plasma process. When the GDL is covered by a perforated plate, only the uncovered areas of the surface of the GDL will be modified in the plasma process. Consequently, the uncovered areas of the surface of the GDL show hydrophilic properties after plasma treatment (water droplets adhering to these areas – Figure 2), whereas the covered areas of the surface of the GDL retain their initial hydrophilic properties.

2. Proven results: Fuel cells show higher performance

The fuel cells with plasma treated GDL show significantly higher cell voltages than the reference fuel cells without plasma treated GDL. This is due to the fact that the membrane of a fuel cell without plasma treated GDL runs dry, especially at higher current densities. When using a plasma treated GDL, a certain amount of water can be retained in the cell leading to a better fuel cell performance.

Plasma technology can boost your performance in many ways. Contact us to find out how we can customize or standardize our systems for your challenges – let us help to fuel your innovations, too.

 

 

References

[1]          M. Walker, K.-M. Baumgärtner, M. Kaiser, J. Kerres, A. Ullrich, E. Räuchle, J. Appl. Polym. Sci., 1999, 74, 67-73.

[2]          M. Walker: Fuel Cells. [online] Homepage: University of Stuttgart, Institute of Interfacial Process Engineering and Plasma Technology (IGVP)

URL: https://www.igvp.uni-stuttgart.de/en/research/plasma-technology/processes/fuel-cells/ [status: June 16, 2021].

유사한 게시물

항목
Power-to-X Applications / 마이크로웨이브 기술 Empowering Zero Emission: Duo-Plasmaline Driving Performance and Efficiency of Fuel Cells
How plasma technology solves the challenge of performance degradation in fuel cells Fuel cells based on ionomer membranes are very important in applications such as …
더 알아보기
항목
Power-to-X Applications / 마이크로웨이브 기술 3 Good Reasons to Consider Duo-Plasmaline for your Photovoltaic Applications
How Duo-Plasmaline systems open new horizons for growing markets Solar power remains an almost inexhaustible reserve of energy on our scale, as well as being …
더 알아보기
항목
Power-to-X Applications / 마이크로웨이브 기술 The Future of Battery Technology: Empowered by Duo-Plasmaline Systems
How innovative plasma systems bring silicon anodes into lithium-ion battery applications In 2007 researchers at Stanford University discovered a solution to the challenges associated with …
더 알아보기
항목
Power-to-X Applications / 마이크로웨이브 기술 / 반도체 Duo-Plasmaline for Green Technology: 생산성 및 처리량에서 항상 한 발 앞서
DUO-PLASMALINE 시스템이 지속 가능한 에너지 어플리케이션에 어떻게 전력을 공급하는지 모두는 건강한 행성에서 살길 원합니다! 모든 산업의 혁신가들은 더 깨끗한 미래를 위해 열심히 노력하고 있습니다. 무배출 자동차 배터리와 flexible 태양광 발전 패널 제조 관련 …
더 알아보기

Tel.: +49 (0) 6164 – 9307 – 0

Fax: +49 (0) 6164 – 9307 – 93

info@muegge.de

MUEGGE Group

Hochstrasse 4 – 6

64385 Reichelsheim

Germany

Tel.: +1-209-527-8960

Fax: +1-209-527-5385

sales@muegge-gerling.com

Gerling Applied Engineering, Inc.

P.O. Box 580816

Modesto, CA 95358-0816

USA

Tel.: +49 (0) 6164 – 9307 – 0

Fax: +49 (0) 6164 – 9307 – 93

info@muegge.de

MUEGGE Group

Hochstrasse 4 – 6

64385 Reichelsheim

Germany

Tel.: +1-209-527-8960

Fax: +1-209-527-5385

sales@muegge-gerling.com

Gerling Applied Engineering, Inc.

P.O. Box 580816

Modesto, CA 95358-0816

USA

MUEGGE
제품.

개별 프로세스를위한 특별한 솔루션이 필요하십니까?